Emergency Mode

"BATTERYLOW" : If a time average of the battery voltage falls below a threshold, the comm. controller transmits this frame and turn the PDA and APD off to save electricity.

"OVER CURRENT" : If a overcurrent consumption is observed just after an activation of the satellite, the comm. controller transmits this frame and reset the satellite.